关于英语实验报告

  关于英语实验报告

  Determination of heavy metals in soil byatomic absorption spectrometry(AAS)

  Name: XuFei Group: The 3rd group

  Date: Sep. 20th 20xx

  Part 1 The introduction

  1.1The purposes

  (1)Learn how to operate the atomic absorption spectrometry;

  (2)Learn how to do the pretreatment of soil samples;

  (3)Get familiar with the application of atomic absorption spectrometry.

  1.2The principles

  Atomic Absorption Spectrometry (AAS) is a technique for measuring quantities of chemical elements present in environmental samples by measuring the absorbed radiation by the chemical element of interest. This is done by reading the spectra produced when thesample is excited by radiation. The atoms absorb ultraviolet or visible light and make transitions to higher energy levels .

  Atomic absorption methods measure the amount of energy in the form of photons of light that are absorbed by the sample. A detector measures the wavelengths of light transmitted by the sample, and compares them to the wavelengths which originally passed through the sample. A signal processor then integrates the changes in wavelength absorbed, which appear in the readout as peaks of energy absorption at discrete wavelengths. The energy required for an electron to leave an atom is known as ionization energy and is specific to each chemical element. When an electron moves from one energy level to another within the atom, a photon is emitted with energy E. Atoms of an element emit a characteristic spectral line. Every atom has its own distinct pattern of wavelengths at which it will absorb energy, due to the unique configuration of electrons in its outer shell. This enables the qualitative analysis of a sample.

  The concentration is calculated based on the Beer-Lambert law. Absorbance is directly proportional to the concentration of the analyte absorbed for the existing set of conditions. The concentration is usually determined from a calibration curve, obtained using standards of known concentration. Calibration Curve Method: Prepare standard solutions of at least three different concentrations, measure the absorbance of these standard solutions, and prepare a calibration curve from the values obtained. Then measure the absorbance of the test solution adjusted in concentration to a measurable range, and determine the concentration of the element from the calibration curve.

  Part 2 The materials and apparatus

  Atomic absorption spectrometry; Cu hollow cathode lamp; AC voltage stabilizer; oil-free gas compressor; acetylene cylinder; oscillator; sample boat; Erlenmeyer flask with stopper (100 ml); beaker; graduate cylinder; pipette.

  Part 3 The procedure

  3.1 operating procedure for AAS

  (1) inspect major components to ensure operating normal.

  (2) Install required hollow cathode lamp. Select “T” before turning to the power and hollow cathode lamp. Then select appropriate la mp current and preheat for 30min.

  (3) Make sure electrical meter to point to zero and then turn on high-voltage power.

  (4) Select appropriate slit width.

  (5) Rotate monochromator and select required wavelength. If the power meter is too high or low, adjust negative high voltage until the meter reads full scale.

  (6) Adjust light point and wavelength so that the meter represents the maximum value.

  (7) Turn on air compressor and acetylene gas and ignite flame. Adjust the flame appropriately and preheat the burner.

  (8) Inject distilled water into the flame and continue to preheat the burner. Inject distilled water into the flame after each sample.

  (9) Select “E”, inject blank solution into the flame and adjust the meter to zero.

  (10) Optimize analysis conditions and measure standard solution and samples.

  (11) After completion of measurement, turn off acetylene gas valve and then air compressor, cut off gas supply a moment later.

  (12) Select “T” before turning off high voltage power, decrease lamp current and then turn off the lamp. At the same time, all buttons should be on original positions.

  (13) Check the equipment before leaving the laboratory.

  3.2 Determination of soil samples

  (1) Preparation of extracting solution (0.05 mol/l EDTA solution)

  18.6 g of EDTA is dissolved with water in a beaker (500 ml). The PH is adjusted to 7.0 using dilute ammonia. The mixture is transferred into a volumetric flask (1000ml), dilute to the mark and mixed well.

  (2) Treatment of soil samples

  2.50 g of air-dried soil (60- 100 mesh) is put into an Erlenmeyer flask with stopper (100 ml). 12.5 ml of EDTA solution is added. The mixture is shaken for 1h and then filtered. The filtrate is preserved for analysis.

  (3) Preparation of Cu standard stock solution

  0.10 g of Cu is dissolved in 15 ml of (1:1) nitric acid solution. The mixture is transferred into a volumetric flask (1000 ml) and diluted to the mark with re-distilled water. The concentration of the stock standard solution is 100g/ml. (The concentration should be calculated according to the mass of Cu).The working Cu standard solution (10μg/ml) is obtained by diluting 10 ml of Cu standard stock solution to 100 ml with

  re-distilled water.

  (4) Plotting of the standard curve

  0 ml, 1 ml, 2 ml, 3 ml, 4 ml and 5 ml of Cu standard solution (10μg/ml) are added respectively to 6 volumetric flask (10 ml) with 1 ml of 5 mol/l hydrochloric acid. The mixture is diluted with re-distilled water and mixed well to give 0μg/ml, 1.00μg/ml,2.00μg/ml, 3.00μg/ml, 4.00μg/ml, 5.00μg/ml of Cu, respectively. The absorbance is measured at wavelengths of 3247 ?. The standard curve is constructed by plotting absorbance vs. concentration.

  (5) Determination of samples

  The sample solution is analyzed using the same procedure and conditions as for the standard curve. The concentration of Cu is obtained from the standard curve based on the absorbance.

  Part 4 The results

  4.1 The raw data

  4.2 AAS standard curve

  4.3 Calculation

  The absorbance of sample is 0.0511.

  According to the formula above :y=0.0446x+0.0024,R2=0.9997

  The concentration of Cu in the sample is:1.091mg/L.

  Part 5 Discussion

  In this experiment, we use the AAS to determine Cu in soil. I learn how to operate the AAS and the limitation. In the experimental process, standard solution was prepared in strict accordance with the experimental requirements and I learn how to deal with the data. Finally we get the standard curve, then, the sample concentration is calculated according to the absorbance of the sample.

  In the experiment we have nine members in our group, so we can do our best in every work we need to do. For my work, I am responsible for the preparation of solution and titration. What’s more, I learn how to use and operate the AAS on the computer later.

  Ultimately, we get the linear formula is y = 0.0446x + 0.0024 and R2=0.9997. From According to the formula and the absorbance of Cu in the sample is 0.0511, we draw the concentration of Cu in the sample is 1.091μg/ml. We have known that the concentration of test sample measured by instrument is 1.091mg/L.

  We can say our result of experiment is so very accurate from the standard curve of Cu and the value of R(R2=0.09997). The accurate data is due to the efforts of we everyone. Thanks for every members of our group.

  I have some suggestions for our experiments. Firstly when we’ll do an experiment, we must prepare our pre-lab by ourselves and translate it into Chinese .Only do like this, we can understand the experiment well. Secondly we should prefer to solute the problems in the experiment rather than ask for TA. Finally, everyone should understand his own task in the experiment.

原创文章,作者:fanwen,如若转载,请注明出处:https://fanwen.hongwu.com/18560.html

(0)
上一篇 2022年8月1日 下午3:54
下一篇 2022年8月1日 下午3:56

相关推荐

  • 小音箱实验报告资料范文

      一、装配要点:   装配前识别不同的元器件,以及判别所装配的元器件性能的好坏,是保证装配电子产品质量的重要步骤。识别元器件及参数,需要具备相关知识;而判别元器件性能的好坏可通过…

    实验报告 2022年12月19日
  • 广场园林规划实验报告模板

      一、实训目的:   以园林规划设计系列课程为主,结合有关专业课程而进行的综 合性实习。主要是通过现场考察、分析和自己动手参加实际操作等环节,学习园林绿地、园林建筑、园林工程材料…

    实验报告 2022年10月5日
  • 高中物理实验报告范文

      (一)实验目的   1.学会用打上点的纸带研究物体的运动。   2.掌握判断物体是否做匀变速运动的方法。   3.会利用纸带测定匀变速直线运动的加速度。   4.练习使用打点计…

    实验报告 2022年7月26日
  • FSK调制解调实验报告

      一、实验目的:   1.掌握FSK(ASK)调制器的工作原理及性能测试;   2.掌握FSK(ASK)锁相解调器工作原理及性能测试;   3. 学习FSK(ASK)调制、解调硬…

    实验报告 2022年10月11日
  • 锥体上滚的实验报告范文

      篇一:锥体上滚实验   今天老师给我们开了演示实验,让我们大开眼界,受益匪浅。在这节课里老师给我们演示了好多实验。最让我感兴趣的是锥体上滚。当我看到这个实验时,眼看着一个椎体从…

    实验报告 2022年8月6日
  • 智力竞赛抢答装置实验报告

     智力竞赛抢答装置实验报告   一、实验目的   1、学习数字电路中D触发器、分频电路、多谐振荡器、CP时钟脉冲源等单元电路的综合运用;   2、熟悉智力竞赛抢答器的工作原理;  …

    实验报告 2022年9月22日
  • 实验报告的心得体会

      1.准备越充分,实验越顺利。   古人云,磨刀不误砍柴工。前期的知识储备、文献储备、材料准备、方法准备可以避免手忙脚乱,充分的预实验使你充满信心。一步一个脚印,就不必“从头再来…

    实验报告 2022年7月16日
  • 氯化钠的提纯实验报告范文

      篇一:粗盐提纯实验报告   一、实验目的:   1.学会化学方法提纯粗盐,同时进一步精制成试剂级纯度的氯化钠提供原料.   2.练习天平的使用,以及加热、溶解、过滤、蒸发和结晶…

    实验报告 2022年9月29日
  • 测平均速度的实验报告范文

    篇一:测量平均速度实验报告   指导老师:   实验目的:练习使用刻度尺和秒表,测量小车的平均速度实验原理:速度=距离s用符号表示V=时间t   实验器材:木块木板小车刻度尺秒表实…

    实验报告 2022年10月4日
  • 家兔血压调节实验报告范文

      (一)实验项目:家兔动脉血压调节   (二)实验目的:   1、掌握神经体液因素及受体阻断或兴奋药物对家兔心血管活动的影响机制。   2、掌握动脉血压作为心血管功能活动的综合指…

    实验报告 2022年7月16日

发表回复

您的邮箱地址不会被公开。 必填项已用 * 标注